Home > Post Error > Post Error 1792

Post Error 1792

No data has been lost. Any help is appreciated. 0 Comment Question by:kopite47 Facebook Twitter LinkedIn Email https://www.experts-exchange.com/questions/26579975/RAID-1-Array-failing-causing-system-reboots.htmlcopy LVL 9 Best Solution byvanbarsoun I would update RAID driver and firmware. You'll be best to shutdown the host to replace the drive. 0 Serrano OP Payson Solutions Group Aug 2, 2010 at 3:27 UTC Payson Solutions Group is an All rights reserved. weblink

First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. you are over 3 yeard behind...this will improve monitoring,stability on the drivesNext, update driver and software for the storage subsystem (controller driver and ACU version) for better recognition of the new The drive did not fail until the second occurance of the issue and error two days later. Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/HP-Proliant-Post-Error-1792-Drive-Array-Reports-Valid-Data-found/td-p/5294361

Data Loss possible.In SLot 3 we have the Smart Array E200 Controller lookin fine in HP System Mgmt Homepage, and so does the accelerator. First, Just open a new email message. Login.

In-fact, most of the businesses are now establishing their entire organizational structure around the IT capabilities. Regcure found over 2500 errors including the Windows Post Error: 1792-drive Array Reports Valid Data Found In Array Accelerator and fixed them all. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required. template.

We Acted. Article by: Alex Data center, now-a-days, is referred as the home of all the advanced technologies. By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/POST-Error-1792-Drive-Array-Reports-Valid-Data-Found-in-Array/td-p/4118034 Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required.

Printer Migrator Terminal 2008 Server - Install mode Microsoft Dynamics GP - Add-on Software Blackberry Torch - Enterprise Activation HP Proliant - Post Error: 1792 Drive Array Reports... i tried to update the firmware with BIOS, but still the same. The raid should then rebuild the disk automatically, but you can check within Insight Manager (if you use it) for the progress of the disks rebuild 0 Mace Go to Solution 3 Participants vanbarsoun LVL 9 SBS3 Server Hardware1 mavaks LVL 4 Server Hardware1 SBS1 kopite47 3 Comments LVL 4 Overall: Level 4 Server Hardware 1 SBS 1

Screen shot enclosed.What has to be done?Kind regards,Arthur Heller/Atos Origin/Vienna. 296935.pdf ‏85 KB 0 Kudos Reply All Forum Topics Previous Topic Next Topic 4 REPLIES Víctor Cespón Honored Contributor [Founder] Options https://access.redhat.com/solutions/131793 Perform orderly system shutdowns to avoid leaving data in the array accelerator. The system tells me it is rebuilding the array but when it gets to around 50% - 60% the system just reboots as if someone just pulled the plug (no blue Do not restart that box.  If you have an amber light on the drive you do NOTHING except get a replacement drive in ASAP.  That lights means "REPLACE ME NOW".  It's

Join the community of 500,000 technology professionals and ask your questions. have a peek at these guys I've gotten drives shipped direct from Seagate with data on them already! 0 This discussion has been inactive for over a year. Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as Join Now For immediate help use Live now!

I called hp and after diagnose they replaced the memories and system board. All rights reserved. No indication in the report as to which drive could be the issue of the read/write stops/lockup? http://exactcomputerrepair.com/post-error/post-error-1792-ml350-g5.html Get 1:1 Help Now Advertise Here Enjoyed your answer?

Learn More Red Hat Product Security Center Engage with our Red Hat Product Security team, access security updates, and ensure your environments are not exposed to any known security vulnerabilities. If the issue is still present, run ADU, version 7.31 or later ("Array diagnostic software" on page 76). Action: No action is required.

This video is a short introduction to PRTG, as an initial overview or as a quick start for new PRTG users.

NOTE: If the download link doesn't work you may need to Download it Directly from a Mirror Here. Join & Ask a Question Need Help in Real-Time? Open Source Communities Subscriptions Downloads Support Cases Account Back Log In Register Red Hat Account Number: Account Details Newsletter and Contact Preferences User Management Account Maintenance My Profile Notifications Help Log I have no idea if this is related to the amber light on the disk.

No data has been lost. Am I still at risk?  I am definitely not going to restart the server until I replace the drive, but I have already escalated this issue.  0 Mace Get 1:1 Help Now Advertise Here Enjoyed your answer? this content The other disks in that array are probably the same age and have the same usage and so are also likely to experience a failure.

I would shut down, swap the drives out and then go into the RAID utility on restart. you have an old drive and you shut down and swap it as a replacement for a failed drive. It SHOULD not bring the array offline and instead give a drive bay Good thing there was no data on that drive.  0 Serrano OP Justin2100 Jul 20, 2010 at 4:12 UTC What if I just remove the drive?  0 Maybe the question we need to ask is What drives are in what RAID arrays?

Join the community Back I agree Powerful tools you need, all for free. That can be fixed so it 'works around' agai… Windows 10 SBS Rename and move Database and log to new volume in Exchange 2013/2016 Video by: Alan This video discusses moving Perform the actions recommended by the diagnosis report. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required.

Thanks 0 Featured Post How to run any project with ease Promoted by Quip, Inc Manage projects of all sizes how you want. Join & Ask a Question Need Help in Real-Time? Causes of the error: Windows Windows Post Error: 1792-drive Array Reports Valid Data Found In Array Accelerator are caused by misconfigured system files. Could it be an outdated array controller driver?  0 Pure Capsaicin OP Scott Alan Miller Jul 20, 2010 at 4:08 UTC Niagara Technology Group (NTG) is an IT

One of the first things to try is searching for files that shou… Server Hardware Using the 'Connect to a Computer' section of the Remote Web Workplace site on a Windows Posted by Blu3yy at 10:11 Reactions: Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest No comments: Post a Comment Newer Post Older Post Home Subscribe to: Post Comments (Atom) Blog Archive Download Now: Windows Error Repair Tool *RegCure Pro will repair Windows Error and registry data errors on your PC Compatible with ALL Versions of Windows Including Windows 7 and 8 Posted Product Security Center Security Updates Security Advisories Red Hat CVE Database Security Labs Keep your systems secure with Red Hat's specialized responses for high-priority security vulnerabilities.