Home > Post Error > Post Error 1719

Post Error 1719

Contents

Was supprised at how quick and good the support was though! 0 Datil OP [email protected] Jun 13, 2013 at 11:52 UTC Brand Representative for HP Hello Andy,  No, Satalite Office Set up satellite office. Action: Run Insight Diagnostics if possible and replace failed components as indicated. Since HP just stated that this server is not (yet) officially supported, I suspect that it was either because they ran into issues like you, or because they have not tested check over here

Action: Perform the following steps: Press 1 or 2 Pressing 2 exits the OBDR configuration. OK, in that case it may be a HW issues after all - maybe you got a bad batch. Well, good luck with this.  No problem :-) cheers for trying. Audible Beeps: None Possible Cause: The array controller memory is beginning to fail. Audible Beeps: None Possible Cause: An unsupported redundant cabling configuration for the Smart Array firmware version is installed. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01917689&sp4ts.oid=1157688

Post Error 1719 A Controller Failure Event

Internal CPU Check Error Message Error Message: Internal CPU Check - Processor Audible Beeps: None Possible Cause: A processor has experienced an internal error. CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. Action: Populate the processor socket or remove the DIMM. 207 Error Message #2 Error Message: 207-Invalid Memory Configuration - DIMMs must be installed in pairs or sequentially Audible Beeps: Audible Beeps: Some messages are informational only and do not indicate any error.

Be sure each fan cable is properly connected, if applicable, and each fan is properly seated. Be sure that all installed processors are the same speed. Audible Beeps: None Possible Cause: The system detects that the drives are still present during POST and that the user previously requested them to be removed from the controllers configuration information. Hpe Warranty Check Action: Run ROMPaq Utility to flash the system so that the primary and backup ROMs are valid.

Action: Exchange DIMMs and retest. Post Error 1719 P410i We use original HP ups's and APC Symetra PX ups's.It seem high quality HP PSU require really good online ups.Why do blame HP? Please go to HP Support Center. Action: Lower the room temperature. 1611 Error Message #1 Error Message: 1611-CPU Zone Fan Assembly Failure Detected.

Action: For information on how to cable the device in a supported manner for dual-domain redundant path support, see the product user guide. 1742 Error Message Error Message: 1742-Slot z Drive Hp Warranty Check Action: Reseat LOM in slot. The goal being to provide some replication capabilities with one of them while running ~6 VMs on the other. Action: Power down the server.

Post Error 1719 P410i

Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server. http://h20564.www2.hp.com/hpsc/doc/public/display?docId=mmr_kc-0108397&sp4ts.oid=3182561 Action: Install or reinstall DIMMs to support online spare configuration. 209 Error Message #3 Error Message: 209-Hot-add Memory Configuration - Boards must be installed sequentially. Post Error 1719 A Controller Failure Event Shes checking some stuff while i listen to lovely hold music while she checks some details. 0 Pure Capsaicin OP akp982 Jun 13, 2013 at 10:35 UTC akp982 Post Error 1719 P420i Fatal Hub Link Error Message Error Message: Fatal Hub Link Error Audible Beeps: None Possible Cause: The hub link interface has experienced a critical failure that caused an NMI.

Action: Run Insight Diagnostics and replace failed components as indicated. 224 Error Message Error Message: 224-Power Fault Detected - Flexible LOM 1 (Lan On Motherboard) Note: This error message applies to check my blog Action: Reboot the server. Really a moot point. If the condition persists, then install a replacement battery pack. 1733 Error Message Error Message: 1733-Slot z Drive Array - Storage Enclosure Firmware Upgrade Problem Detected... ...Port x box y: Enclosure Fbwc

The drives should be accessible through the remaining path. Action: Action: Run Insight Diagnostics and replace failed components as indicated. We ended up just sending them some completely unrelated capture. this content Action: Refer to the server documentation for supported processors.

Be sure a diskette drive is cabled properly, if a diskette drive exists. The information provided is provided "as is" without warranty of any kind. Type ".hh dbgerr004" for details Page 7d3000 not present in the dump file.

The system will run in Full Performance mode.

Open Source Communities Comments Helpful 3 Follow Why system rebooted after message "POST error 1719 : A controller failure event occurred prior to this power-up" ? If this message persists, you may need to replace the onboard battery. 163 Error Message Error Message: 163-Time & Date Not Set Audible Beeps: 2 long Possible Cause: Invalid time or Need access to an account?If your company has an existing Red Hat account, your organization administrator can grant you access. Action: If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and restore all data afterward If this drive is part of a fault-tolerant

SUPPORT COMMUNICATION - CUSTOMER ADVISORY Document ID: c04325462 Version: 4 Advisory: (Revision) HP ProLiant Servers - HP Smart Array P212/P410/P410i/P411/P711m/P712m/P812 Controllers Configured with One or More Spare Drives and Firmware Version I booted the server into windows and immediately started prime95. If you've done the FW as you say, then its time to start ruling out components. http://exactcomputerrepair.com/post-error/post-error-1719-bl465c-g7.html Action: Replace the power supply. 1615 Error Message #1 Error Message: 1615-Power Supply Configuration Error Audible Beeps: None Possible Cause: The server configuration requires an additional power supply.

I'd suggest once you swap that one out to install the existing one as the second power supply and run it for a bit. 0 Jalapeno OP Pctaco Be sure no keys are depressed or stuck. Additional logical drives will not be added to the configuration. Port x box y: Unable to read firmware version of one or more components Audible Beeps: None Possible Cause: An incorrect enclosure firmware version is installed or an enclosure firmware upgrade

Action: Contact an authorized service provider. Tags: [email protected] 2 Tabasco OP Kev840 May 1, 2015 at 7:53 UTC +100 for Priscilla, she's the bomb!  Helped me get lots of stuff resolved in a jiffy. Well see how this goes... 0 Pure Capsaicin OP akp982 Jun 13, 2013 at 10:25 UTC akp982 is an IT service provider. For embedded PCI devices, run Insight Diagnostics and replace any failed components as indicated.

NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document . Refer to the server documentation. Action: Be sure the keyboard and mouse are connected. Audible Beeps: 1 long, 1 short Possible Cause: Processor and/or processor stepping is not supported by the current system ROM.

Sequential write operations to the affected blocks should resolve the media errors. 1717 Error Message Error Message: 1717-Slot z Drive Array Controller - Disk Drive(s) Reporting OVERHEATED Condition Audible Beeps: None Hmmm so i'm talking to myself in here... Ours is as follows:Part Number: 583970-421 DL380 G7 - 2xXeon X5660/2.8Ghz, 2x750W PSU, Smart Array P410i/1G FBWCMemory: 60GB (6x2GB and 6x8GB)Storage: 2x 72GB 6G SAS 15K SFF Dual Port (Mirrored)3 x Floppy Drive Error Message Error Message: No Floppy Drive Present Audible Beeps: None Possible Cause: No diskette drive is installed or a diskette drive failure has occurred.