Home > Post Error > Post Error 1719 P420i

Post Error 1719 P420i

Contents

Browse other questions tagged raid hardware hp hp-proliant hp-smart-array or ask your own question. The information provided is provided "as is" without warranty of any kind. Running HP Smart Array Controller Firmware Version 4.68. What do you do with all the bodies? check over here

Controller firmware was 2.52, Hardware Revision: B. To search for additional advisories related to HP Embedded Smart Array P220i or P420i Controllers, use either of the following search strings: +Advisory +ProLiant -"Software and Drivers" +"Smart Array P220i" OR The system is NOT configured with a SAS/SATA backplane expander. share|improve this answer answered Jun 24 '11 at 13:30 Chris S 70.2k789184 Couldn't agree more Chris, this looks like either a suspect controller or possibly an issue with the Bonuses

1719 - A Controller Failure Event Occurred Prior To This Power-up

share|improve this answer answered Jan 11 '15 at 14:10 ewwhite 153k49303583 Windows Server 2012 R2 Data Centre, No all lights are green.. End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto We had incidents where drives were marked as "failed" but nothing wrong with the drive whatsoever.

etc.)I just hope that HP know about the issue and are already working on a fix !Out of curiosity, hum much memory do you have in your servers ? Other product and company names mentioned herein may be trademarks of their respective owners. up vote 0 down vote As it news, I would call for the board warrenty. Updated RAID to v3.52, even all the disks got an new firmware.

Open Source Communities Comments Helpful 3 Follow Why system rebooted after message "POST error 1719 : A controller failure event occurred prior to this power-up" ? Post Error 1719 P410i The system is NOT configured with a SAS/SATA backplane expander. This document is subject to change without notice. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c03787389&lang=en-us&cc=us Then, after reboot, I get the same RAID errors as you guys get: POST Message 10/30/2010 19:37 10/30/2010 19:32 2 POST Error: 1719 - A controller failure event occurred prior to

How were Western computer chips reverse-engineered in Soviet Russia? When this occurs, the following Power-On Self-Test (POST) and Integrated Management Log (IML) error messages will be generated: POST Error Message 1719-Slot 0 Drive Array - A controller failure event occurred I've now disabled the write cache on the array controller for that server to see if it still re-occurs. Change product Choose from all HPE products Enter product serial number Please wait while we process your request.

Post Error 1719 P410i

Would Earth's extraterrestrial colonies have a higher average intelligence? Read More Here Now, the server hangs once or twice a week, most of the time in the weekends, ESX is unresponsive except for the the ALT-F11 screen: this gets filled with SCSI errors. 1719 - A Controller Failure Event Occurred Prior To This Power-up Spent â ¬ 8000 on a server that randomly hangs with SCSI problems. A Controller Failure Event Occurred Prior To This Power Up 0x13 When the server is restarted, the lockup event will be indicated by the following POST error: 1719 - Slot X Drive Array - A controller failure event occurred prior to this

If you cannot find your product on this site, go to HP Support Center. check my blog Sign up for Subscriber's Choice at the following URL: http://www.hp.com/go/myadvisory NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant How should I form grammatical cases in my conlang? The product could not be added to your profile at this time. Post Error: 1719-a

Hewlett Packard Enterprise Company shall not be liable for technical or editorial errors or omissions contained herein. Please wait while we process your request. Help! this content Why would a NES game use an undocumented 1-byte or 2-byte NOP in production?

i then get a warning in yellow saying there is errors, press F1 to continue or F2 to view them, pressing F2 takes me to 'Device Health Status' which shows: Embedded Running the HP ProLiant Scripting Toolkit Version 9.20 through 9.50. Hewlett Packard Enterprise Company shall not be liable for technical or editorial errors or omissions contained herein.

Calling HP now to get a replacement P410i. 0 Kudos Reply « Previous 1 2 3 4 Next » The opinions expressed above are the personal opinions of the authors, not

Setup as RAID-5 with 5x 1T drives, after SSD over-provision you get about 3.5T in VMWare datastore. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Anyone with a solution? 0 Kudos Reply BrightMinds Frequent Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎11-11-2010 09:05 The system is NOT configured with SAS/SATA Solid State Drives (SSDs).

I was hoping we could get specifics on the meaning of the error code. –ewwhite Jun 24 '11 at 15:57 Definitely premature failure. SEARCH TIP : For hints on locating similar documents on HP.com, refer to the Search Tips document . Since the ESX server is live, I can now replace it myself whenever I feel fit. have a peek at these guys This document is subject to change without notice.

Transpile WordMath One week to go in the final PhD submission and I have lost the will to work on it. there is another controller on it's way to me. –Goodbytes Jan 12 '15 at 15:28 | show 1 more comment Did you find this question interesting? Open Source Communities Subscriptions Downloads Support Cases Account Back Log In Register Red Hat Account Number: Account Details Newsletter and Contact Preferences User Management Account Maintenance My Profile Notifications Help Log asked 5 years ago viewed 4827 times active 1 year ago Related 1hp smart array lock up code 0x15, what is that? (or where can I get a list of descriptions

Explore Labs Configuration Deployment Troubleshooting Security Additional Tools Red Hat Access plug-ins Red Hat Satellite Certificate Tool Red Hat Insights Increase visibility into IT operations to detect and resolve technical issues Word that includes "food, alcoholic drinks, and non-alcoholic drinks"? The information provided is provided "as is" without warranty of any kind. See attached screenshot.

RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Instability was observed BOTH in systems where we got "Initialization Completed" status and also where it got "Initialization Failed" status. Thanks –Goodbytes Jan 11 '15 at 14:27 Your cache module failed. The information in this document is subject to change without notice.

The system appeared available and responded to pings, but all I/O access stalled (the system load must have been 100+).