How to prepend and append tokens to a macro definition in the current scope only? Action: Run Insight Diagnostics and replace any failed components as indicated, including processors and PPMs. Action: Exchange DIMMs and retest. CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. check over here

HP is not liable for blocked data access caused by improper TPM use. Action: Run Insight Diagnostics and replace any failed processors or reseat any loose processors. You'll need the 2008R2 driver for it, and all will work fine. share|improve this answer answered Jun 24 '11 at 13:30 Chris S 70.2k789184 Couldn't agree more Chris, this looks like either a suspect controller or possibly an issue with the

Action: Install the required additional power supply. 1615 Error Message #3 Error Message: 1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure in Bay X Audible Beeps: None Possible See the product QuickSpecs or User Guide for supported memory configurations. 207 Error Message #6 Error Message: 207-Invalid Memory Configuration - Insufficient Timings on DIMM Audible Beeps: 1 long, 1 short I don't know personally, but i wonder if i'd be able to swap out the P410 w/ a P222 and use the built-in as well w/out losing data.

It also works in Intelligent Provisioning from what I'm told (I haven't tested it, but I'm reasonably confident there). Please check DIMM compatibility. - Some DIMMs may not be used Audible Beeps: None Possible Cause: Invalid or mixed memory types were detected during POST. Please re-enable javascript to access full functionality. If the problem persists, replace the failed cooling fans.

Action: Populate each node with the same memory configuration and enable interleaving in RBSU. Action: Check the System Management Log or OS Event Log for details on the failure. Action: Do one of the following: Install a valid FBDIMM pair if the system does not support single channel memory mode. my review here This is not an error.

Audible Beeps: 1 long, 1 short Possible Cause: Installed memory module is an unsupported size. Remove some of the devices attached to the controller. 1719 Error Message Error Message: 1719-Slot z Drive Array - A controller failure event occurred prior to this power-up (previous lock-up code Be sure each fan cable is properly connected, if applicable, and each fan is properly seated. HP said, pop in the supported controller and we'll help you...

Sorry about that. Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Action: Refer to the applicable server user guide memory requirements and replace with supported DIMMs. Type ".hh dbgerr004" for details Page 7d3000 not present in the dump file.

If this message persists, you may need to replace the onboard battery. 163 Error Message Error Message: 163-Time & Date Not Set Audible Beeps: 2 long Possible Cause: Invalid time or check my blog To sum up, your P410 controller will work --you'll just miss out on a lot of cool things you'd get with a P222 or P421, and if you're running the server Creating your account only takes a few minutes. By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks.

Backup and restore recommended. For more information, see the HP BladeSystem c-Class Enclosure Troubleshooting Guide on the HP website ( http://www.hp.com/support/BladeSystem_Enclosure_TSG_en ). 1735 Error Message Error Message: 1735-Slot z Drive Array - Unsupported Redundant Cabling Array Accelerator will be reenabled when additional battery packs are installed. this content Action: For information on how to cable the device in a supported manner for dual-domain redundant path support, see the product user guide. 1742 Error Message Error Message: 1742-Slot z Drive

Smart Array Controllers configured with SAS HDDs or SSDs are NOT affected. OK, in that case it may be a HW issues after all - maybe you got a bad batch. Well, good luck with this.  No problem :-) cheers for trying. If this message goes away after you remove the new hardware, there may be a problem with the expansion add-in board.

Type ".hh dbgerr004" for details Page 7d3000 not present in the dump file.

Pressing 1 starts the OBDR configuration.The following message appears: Attempting to enable OBDR for the attached USB tape drive... Binary to decimal converter Drunk man with a set of keys. i've got a support contract and everything and the support guy is telling me the support case will fix itself if i install a compatible controller... Action: Press the F1 key to record the new configuration.

Migrate logical drives to RAID 5 or upgrade to a larger array accelerator module. 1711 Error Message #2 Error Message: 1711-Slot z Drive Array - Stripe size too large for RAID Maybe if they actually had other options for supported cards or really, just more than one, this wouldn't be a problem. Action: Run the server setup utility and correct the configuration. have a peek at these guys Shes checking some stuff while i listen to lovely hold music while she checks some details. 0 Pure Capsaicin OP akp982 Jun 13, 2013 at 10:35 UTC akp982

Action: No action is required. 1725 Error Message Error Message: 1725-Slot X Drive Array-Optional SIMM Failure Detected Audible Beeps: None Possible Cause: SIMM has been automatically disabled due to memory errors Action: Check the fans to be sure they are installed and working. See if a serial port card is installed that uses jumpers or switches for the Com Port address. To read the Post error message on screen the video sub-system of the server must be working.

Allow 15 minutes for the process to complete. Back to top #14 PetieG PetieG HSS Member Members 38 posts Posted 13 February 2014 - 08:26 AM Thanks guys...I really appreciate it. Action: Run Insight Diagnostics to identify failed DIMMs. Audible Beeps: Audible Beeps: None Possible Cause: The NMI button was pressed, initiating a memory dump for crash dump analysis.

Action: Disconnect the redundant SAS cables, and then update the Smart Array firmware to the correct version. 1736 Error Message Error Message: 1736-HP Trusted Platform Module Error Audible Beeps: None Possible Assembly will provide adequate cooling. The system configuration has changed since the last boot (addition of a hard drive, for example) or a loss of power to the real-time clock has occurred. If a known working replacement fan is not spinning, replace the fan cage assembly. 1611 Error Message #9 Error Message: 1611-Power Supply Zone Fan Assembly Failure Detected.

TECHNOLOGY IN THIS DISCUSSION HP 362269 Followers Follow Hewlet Packard Join the Community! Venting, frustrated... Action: Replace the failed cooling fan. 1612 Error Message Error Message: 1612-Primary Power Supply Failure Audible Beeps: 2 short Possible Cause: Primary power supply has failed. Action: Install a memory module of a supported type.