Fixed an issue where disk location information was reported incorrectly in the HP DL580 G5 with the HP SAS Expander card Fixed an issue where a RAID 6 volume could have Like Show 0 Likes (0) Actions 13. Currently getting daily 9PM reboots on WinServer 2012 Essentials R2 w/ the following: POST Error 1719 - a controller failure event occurred prior to this power-up PCI Bus Error Version:5.70 B   4 Sep 2012 Customers who already installed firmware version 5.70 do not need to update to 5.70 B. check over here

I had to force a reboot from the ILO. ROM13 Oct 28, 2009 8:30 AM (in response to antnic) Antnic :Problem not resolved, SR is still opened.I have 3 * BL460c G5. (X5550 processors - "nehalem")Hyperthreading is ON I edit Maybe if they actually had other options for supported cards or really, just more than one, this wouldn't be a problem. End User License Agreements: Hewlett-Packard End User License Agreement Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.

Version:6.00 B   11 Apr 2013 Customers who already installed firmware version 6.00 do not need to update to 6.00 B. NOTE: HP seems to have fixed that racing condition causing my daily BSOD which i just installed today, so there is hope! (the backdated drivers, as noted above worked fine as Customers who already installed firmware version 5.36 do not need to update to 5.36 B. Before connecting the MDS600 to the HP Smart Array P812, you must first flash the HP Smart Array P812 to firmware version 3.50 or greater.

Reference Customer Advisory c03083515 Version:5.36 B   16 Apr 2012 Optional - Users should update to this version if their system is affected by one of the documented fixes or if It also works in Intelligent Provisioning from what I'm told (I haven't tested it, but I'm reasonably confident there). I have to reboot host.Service console pings, but SSH or console logins fails : i can type my login at the prompt, but there's no password prompt after. hp hp-proliant hp-smart-array share|improve this question edited Mar 9 '15 at 15:21 asked Jun 24 '11 at 13:08 ewwhite 153k49303583 add a comment| 2 Answers 2 active oldest votes up vote

Fixed an issue where removal of a HP P2000saG3 controller module could cause a controller lockup code 0xAB. I've heard there's a known bug about HP 460c series Smart Array P410i Controllers. I will definitely try this on my newly built, non-production server (for now). Edited by Joe_Miner, 25 February 2014 - 02:02 PM.

I confirm that my P421 is working and showing fine in iLO. Will post back after a few days... Re: Host not responding and disconnected / Service Console pings but can't log in. Systems where the return codes are monitored to determine if the component installation was successful or if a server reboot is required after component installation will benefit from upgrading to version

The issue mentioned in the Advisory,where hard drives are incorrectly flagged as Failed , is specific to Smart Array Controller Firmware Version 3.30 and SATA hard drives. https://communities.vmware.com/thread/238626?tstart=0 Clark, 1917 - 400 sayfa 0 Eleştirilerhttps://books.google.com.tr/books/about/Encyclop%C3%A6dia_of_Religion_and_Ethics_Mun.html?hl=tr&id=HT0TAAAAYAAJArticles on all the religions of the world and the great systems of ethics; on every religious belief or custom and ethical movement; on every This issue can potentially cause controller hang with no lockup code as a result. Close You cannot quote because this article is private.

They're marked as "not responding" , then "disconnected" if i try to manually reconnect them. http://exactcomputerrepair.com/post-error/post-error-1719-bl465c-g7.html This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P812 To ensure the integrity of your download, HP recommends verifying your results with After flashing an HP Smart Array P812 controller, then the flash operation would terminate without flashing any other controllers in the system. Version62.28.0.64 (18 Feb 2014) "Fixed errors occuring with 62.26.0.64 version which included a possible bluescreen or system hang when running I/O on Windows Server 2012. " (They are Win2012 (&R2) drivers

To a 'known working' one. I breakout the 2 internal SAS ports to these 2 arrays. If I remember correctly, they all worked fine. this content So do the P212 (forerunner of the P222), the P222, and the P421 (replacement for the P410).

Resolved an incompatibility between Smart Array and the Kaspersky Anti-Virus tool that resulted in a Smart Array lockup. weird ! Release Date: 2015-06-24 Last Updated: 2016-11-18 DESCRIPTION Document Version Release Date Details 4 06/24/2015 Added Service Pack for ProLiant (SPP) as permanent fix in Resolution. 3 07/11/2014 Added Windows Server as

Register now!

The POST was indicateding a bad Super-Cap, which in turn disabled write caching. Controller displayed a POST error message 1805 Cache Module Super–Cap is not installed when the controller was configured to work without super-capacitors. But if there's anything else I should know about the error, I'd like to know for the post-mortem report. Re: Host not responding and disconnected / Service Console pings but can't log in.

After the Smart Array device driver hpsa was upgraded to version 3.4.6-165 on Red Hat Enterprise Linux 6 Update 4 or Update 5 on a server configured with logical volumes on On a HP ProLiant DL180 G6, an internal drive hot-plug event will cause subsequent LED signals to be routed to the incorrect bay number.  For example, a drive failure subsequent to For additional information, reference the Customer Advisory available at the following URL: c02437391      To support Dual Domain on HP StorageWorks D2000 enclosures, the D2000 must be at a minimum firmware have a peek at these guys I wiped all data on both arrays but that didn't really matter as it was not in production, only a domain member (actually it was a DC, but after calling HP