However that was not a recommended scenario for returning errors from scripts. For the application command line, it should be a command that calls powershell and runs the script, so something like powershell.exe -executionpolicy unrestricted .\myscriptname.ps1 Wednesday, August 06, 2014 6:11 PM Reply You often have to deal with packages that are not meant to push silently, or push through a task sequence. Use Error handling within your scripts to work through that error. http://exactcomputerrepair.com/error-code/pin-pad-error-code-54.html

AdamParticipant February 12, 2016 at 9:20 pm Post count: 5 #1141 Not sure why it wont let me edit my post, but should I keep -IgnoreExitCodes in the above script? If you add the additional ones as acceptable, you will already be backwards compatible as they will always exit 0. Edited by MrBrooks Wednesday, August 06, 2014 3:52 PM Marked as answer by MyGposts Thursday, August 07, 2014 4:05 PM Wednesday, August 06, 2014 3:45 PM Reply | Quote 0 Sign Escape characters by Baatch 6 days, 21 hours ago Get-MsiTableProperty and MSTFile by ChGrand 2 weeks ago Get-MsiTableProperty and MSTFile by ChGrand 2 weeks ago Picking Effortless Plans In car by https://support.symantec.com/en_US/article.TECH12314.html

Msi Return Code 3010

Initiate a reboot of the virtual machine b. For instance, a task sequence that installs Intel AMT software and drivers pops up a dialog box asking the user to clickto restart now or restart later even though the command Close Login Didn't find the article you were looking for? ERROR_SUCCESS_REBOOT_REQUIRED This isn’t really an error but is just a code stating that the operation completely successfully and requires a reboot to become effective.What Switch is causing the problem?The problematic switches

I think most of these are because the applications are looking for a interactive restart that is not done until the MDT task sequence does a reboot. Remember you only have to use Write-Error and non 0 codes if you want fire and brimstone at the end of your deployments, in response to undesired executions. Multiple-Package Installations cannot run if rollback is disabled. Mainenginethread Is Returning 3010 Verify that the package exists and is accessible, or contact the application vendor to verify that this is a valid Windows Installer package.

Member ferventcoder commented Dec 22, 2015 It still feels like there is an inconsistency, which can lead to weird expectations. Msi Error Code 1603 This documentation is archived and is not being maintained. This will stop the occurrence of the 3010 error and then force the reboot of the client machine. 2. click The script is powershell and successfully installs the software even when executed by SCCM.

My package will return 3010 - reboot required when the script is finished. Error Code 2359303 Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! Escape characters 6 days, 21 hours ago Dan on Box to ask a customer to close his session 1 week, 1 day ago Francois on Box to ask a customer to The script dot-sources the AppDeployToolkitMain.ps1 script which contains the logic and functions required to install or uninstall an application. .PARAMETER DeploymentType The type of deployment to perform.

Msi Error Code 1603

ERROR_INSTALL_SERVICE_FAILURE1601The Windows Installer service could not be accessed. http://stackoverflow.com/questions/24987893/sccm-2012-package-exit-code-failure-for-3010 ERROR_INSTALL_TRANSFORM_REJECTED1644One or more customizations are not permitted by system policy. Msi Return Code 3010 if not then it passes the ReturnValue to the exit code. Windows Installer Error Codes All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback current community chat Stack Overflow Meta Stack Overflow your communities Sign up or log in to customize your list.

Member ferventcoder commented Dec 22, 2015 I just meant because boxstarter can handle the reboots for you. check my blog ERROR_INSTALL_SERVICE_SAFEBOOT 1652Windows Installer is not accessible when the computer is in Safe Mode. Set pipe capacity in Linux How do I reassure myself that I am a worthy candidate for a tenure-track position, when department would likely have interviewed me even if I wasn't? Submit a False Positive Report a suspected erroneous detection (false positive).

Information for: Enterprise Small Business Consumer (Norton) Partners Our Offerings: Products Products A-Z Services Solutions Connect with us: Support Error_success_reboot_required

Not the answer you're looking for? Options: Interactive = Shows dialogs, Silent = No dialogs, NonInteractive = Very silent, i.e. But in this way, it's a little more flexible. this content If it is not true then the script exits with the return code 1.

ERROR_UNSUPPORTED_TYPE1630Data of this type is not supported. Mdt Unexpected Return Code 1 Products Products Home Threat Protection Advanced Threat Protection Endpoint Protection Endpoint Protection Cloud IT Management Suite Email Security.cloud Data Center Security Blue Coat Products Information Protection Data Loss Prevention Encryption VIP During a normal program deployment We'll need logs like smsts.log (if applicable) appdiscovery.log appenforce.log appintenteval.log Can you upload your logs somewhere (like OneDrive) so we can review? Author Posts You

ERROR_PATCH_PACKAGE_REJECTED1643The patch package is not permitted by system policy.

This error often means that a Pre-requisite was not met. (e.g. ferventcoder added Enhancement 0 - Backlog 0 - _Triaging labels Dec 22, 2015 Member ferventcoder commented Dec 22, 2015 @icnocop we do have a stop immediately flag I believe. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Mdt Return Code 1 Related About Andrew Barnes A Scripting and Deployment Specialist.

ERROR_PATCH_NO_SEQUENCE1648No valid sequence could be found for the set of patches. A more complete configuration would be a try catch and log errors, this was meant to be more of a jumping off point :) Wednesday, August 06, 2014 4:54 PM Reply This can lead to very perplexing failures, such as running a successful xcopy that exits with 2 and seeing package failures without understanding why. have a peek at these guys I'm thinking if/maybe when choco has support for this feature, then boxstarter can also be updated to support it, but I believe choco should be first because boxstarter utilizes choco in

Is there any financial benefit to being paid bi-weekly over monthly? Will a tourist have any trouble getting money from an ATM India because of demonetization? Additional reading: Scripting Guy Blogs - Error Handling Windows PowerShell Exit Codes Share this:TwitterFacebookLinkedInGoogleRedditTumblrEmailLike this:Like Loading... ERROR_INSTALL_TEMP_UNWRITABLE1632The Temp folder is either full or inaccessible.

Moon Dust Is it possible to return an object of type T by reference from a lambda without using trailing return type syntax? Default is: Interactive. ERROR_INSTALL_PLATFORM_UNSUPPORTED1633This installation package is not supported on this platform. Keith Garner - Principal Consultant [owner] - http://DeploymentLive.com Intel uses some nonstandard codes.

Wednesday, August 06, 2014 9:27 PM Reply | Quote 1 Sign in to vote you can supress these codes easily.... ERROR_INVALID_FIELD1616The record field does not exist. ERROR_UNKNOWN_PROPERTY1608This is an unknown property. If you feel you are in need of support for a Microsoft product, please go to our technical support site at support.microsoft.com.   Error codeValueDescription ERROR_SUCCESS0The action completed successfully.

ERROR_INSTALL_REJECTED1654The app that you are trying to run is not supported on this version of Windows. Checking `$LastExitCode` checks the last executable's exit code when the script specifically does not call `Exit`. Login with your Social AccountRecent Replies Eric on run psapps directly from a sccm DP (no download in client cach) 5 days, 7 hours ago Dan on Cannot get Execute-Process with When one of those fails, it is easy to say the exit code could be the same for the one that failed.

Wait for the virtual machine to boot and automatically login back into the desktop c. Word that includes "food, alcoholic drinks, and non-alcoholic drinks"? An example would be - #GET CURRENT DIR $mydir = Split-Path -parent $MyInvocation.MyCommand.Path #SET VARAIBLE TO PASS INSTALL COMMAND WITH SPACES $command = @" setup.exe /s "@ #MOVE TO INSTALL DIR ERROR_CALL_NOT_IMPLEMENTED120This value is returned when a custom action attempts to call a function that cannot be called from custom actions.

As this feature may need to be shut off, provide it as both a feature and switches to turn it on/off per install, upgrade, and uninstall. asked 2 years ago viewed 1535 times active 1 year ago Related 0Automated Software deployment through SCCM 2012 using wmi0Powershell SCCM 2012 Moving Driver Package-1Automatically uninstall unused applications in SCCM 20121SCCM Initiate a reboot of the virtual machine b. As this feature may need to be shut off, provide it as both a feature and switches to turn it on/off per install, upgrade, and uninstall.